The DA-2KI is an ISA DC Power supply that is designed to work with Cesium Magnetometers, especially those traditionally used in Geophysical Survey.  Other technologies of Magnetometer are supported given correct settings. Contact DeVita Associates for application information.

DA-2KI Dual Channel DC Power Supply Specification

Picture

    Product Specification Sheet

  • Product Name:    Mag. Power Card, ISA
  • Product Designation Number:  DA-2KI
  • Date of Introduction:  September 16, 2002
  • Revision Date and Number:  September 16, 2002 - Revision 1.0
  • Project Engineer:  Peter M DeVita, P.Eng.
  • Overview:

    The DA-2KI is a dual channel, Cesium Magnetometer Interface card designed for a PC, ISA bus. This unit provides power to two (2) independent Mag's using a coax cable per channel. The returned signal frequency is inductively coupled, filtered and shaped into a TTL compatible output.

    A. Mechanical Specifications:

     

    Item

    value

      1.

    Mag Interface:

    Dual BNC connectors, one per channel

      2.

    Output interface:

    DB9 for digital output and analog output signals

      3.

    PC Interface:

    ISA card edge

      4.

    Dimensions: Length:

    260mm to card edge; +25mm for BNC projection

      5.

     Height:

    125mm from ISA edge connector

      6.

     Thickness:

    ~25mm - overlaps 1 adjacent ISA slot

    B. Power Specifications:

     

    Item

    Value

      1.

    Load on PC: +  5V source:

    ~100mA

     

     +12V source:

    ~ 50mA

     

     -12V source:

    ~ 50mA

      2.

    DC input Mag Power, voltage:

    21 to 32 V in

     

    current :

    6A max

      3.

    DC output to Mag: voltage:

    30VDC nominal; settable per channel from 25 to 35V

     

    current:

    I DC max = 2.0 A per channel

    Note: Interface cable with NATO connector is a standard  option.

    C. Signal Characteristics:

     

    Item

    Value

      1.

    Mag input bandwidth:

    50KHz to 350Khz

      2.

    Sensitivity Range

    50mV to 5V p-p

      3.

    DC Power noise ripple:

    12mv typical with load connected; 150mV DC in ripple

      4.

    Channel cross talk:

    below measurable range

      5.

    Output signals per channel: Digital:

    TTL compatible

     

     Analogue:

    settable to max. gain of 20